Shop By Category

100kDa

Amicon Ultra-15 Centrifugal Filter Unit with Ultracel-100 membrane, 100 KDa 15mL /PK 96

Product Code: MERUFC910096

CAS No: Not Assigned
Merck Website Link

Increase value Decrease value
  • Overview
  • Specifications
  • Contact us
  • Attachments
Overview
Amicon® Ultra-15 centrifugal filter devices for protein purification and concentration provide fast ultrafiltration, with the capability for high concentration factors and easy concentrate recovery from dilute and complex samples . The vertical design and available membrane surface area provide fast sample processing, high sample recovery (typically greater than 90% of dilute starting solution), and the capability for 80-fold concentration. Solute polarisation and subsequent contamination of the membrane are also minimised by the vertical design, and a physical deadstop in the filter device prevents spinning to dryness and potential sample loss. The concentrate is collected from the filter device sample reservoir using a pipettor, while the ultrafiltrate is collected in the provided centrifuge tube. The device can be spun in a swinging bucket or fixed angle rotor.

Advantages:
  • High recovery Ultracel regenerated cellulose membrane in a range of molecular weight cut-offs
  • Vertical membrane reduces concentration polarisation for ultra-fast spin times (as fast as 10-15 minutes)
  • Heat-sealed membrane minimises downstream extractables
  • High retentate recovery of >90%
  • 100% integrity tested for reliable performance
  • Convenient sample monitoring with translucent housing and volume graduations
  • Direct pipette sample access eliminates processing step to recover concentrate
  • High concentration factors of 80-100X
Applications:
  • Concentration of biological samples containing antigens, antibodies, enzymes, nucleic acids, or microorganisms
  • Purification of macromolecular components found in tissue culture extracts or cell lysates and protein removal prior to HPLC
  • Concentration of dilute or pre-purified proteins from column eluents
  • Desalting, buffer exchange, and protein dialysis
  • Size exclusion and protein fractionation
Specifications:
  • Maximum initial sample volume – 15 mL (35? angle fixed rotor is 12 mL)
  • Typical final concentration volume – 200 µl
  • Centrifugal Force Swinging bucket rotor: 4,000 x g; Fixed angle rotor (35?): 5,000 x g
  • Active membrane area – 7.6 cm²
  • Diameter – 2.97 cm
Technical Specifications
Supplier Merck