Climate-friendly and powerful: the ICHeco climate chamber for the stability testing of pharmaceuticals, cosmetics or food works with environmentally-friendly CO2 (R744) as refrigerant. Memmert is thus initiating the climate-friendly future of compressor-cooled temperature control appliances. Furthermore, the ICHeco scores with its unique uniformity of temperature and humidity. Via an air jacket around the hermetically sealed work area, heat is quickly and extensively introduced into the climate chamber over four sides. Icing over of the cooling appliance and sample drying are successfully avoided.

  • Digitally controlled active humidification and dehumidification from 10 to 80 % rh

  • Temperature range from - 10 °C to + 60 °C (models ICHeco / ICH), 0 °C to + 60 °C (models ICHLeco / ICHL)

  • One model variant - TwinDISPLAY

  • Double doors as standard: Prevention of contamination and drops or prevention of rises in temperature with an optimal view of the chamber load through wide-area interior glass doors

A Memmert ICHeco climate chamber offers unique advantages

  • CO2 Refrigerant (R744) is climate-friendly

  • Intuitive and easy-to-use operating menu

  • Temperature and humidity ramps programmable via AtmoCONTROL software

  • Almost exclusive use of high-quality, corrosion-resistant and easily cleanable stainless steel for the working chamber and housing

  • A wide range of options for programming and documentation using interfaces, integrated data logger and software AtmoCONTROL

  • Three years guarantee worldwide

Technical Specifications
Supplier Memmert

ICH110L

Standard delivery Climate chamber

On this page, you can find all the essential technical data on the Memmert climate chamber ICH. Our customer relations team will be pleased to help if you want further information. If you should require a customised special solution, please contact our technical specialists at info@labsupply.co.nz


Sketch Climate chamber ICH110L 

Temperature

Working temperature range without humidity: 0 to +60 °C
Setting temperature range 0 to +60 °C
Working temperature range from +10°C up to +60°C with humidity and/or light
Setting accuracy temperature 0.1 °C
Temperature sensor 2 Pt100 sensors DIN Class A in 4-wire-circuit for mutual monitoring, taking over functions in case of an error

Humidity

Humidity humidity supply with distilled water from external tank by self-priming pump
Humidification humidification by hot steam generator
Humidity active humidifying and de-humidifying adjustable from 10-80 % rh with digital display of relative humidity - resolution of display 0.1 %, setting accuracy 0.5 %

Control of standard components

Light illumination unit consisting of 3 fluorescent lights with cold white light (standard illuminant D65, 6.500K) and 2 UV-lamps in the spectral range of 320-400 nm
Light daylight and UV-light can be programmed individually via controller
Light cold white light +/- 6 %, for UV-light +/- 10 %

Control technology

ControlCOCKPIT TwinDISPLAY. Adaptive multifunctional digital PID-microprocessor controller with 2 high-definition TFT-colour displays.
Language setting German, English, Spanish, French, Polish, Czech, Hungarian
Timer Digital backwards counter with target time setting, adjustable from 1 minute to 99 days
Function SetpointWAIT the process time does not start until the set temperature is reached
adjustable parameters temperature (Celsius or Fahrenheit), fan speed, light, programme time, time zones, summertime/wintertime

Ventilation

Fan forced air circulation in working chamber adjustable from 10 to 100 % in 10 % steps

Communication

Documentation programme stored in case of power failure
Programming AtmoCONTROL software on a USB stick for programming, managing and transferring programmes via Ethernet interface or USB port

Safety

Temperature control mechanical temperature limiter TB, protection class 1 according to DIN 12880 to switch off the heating approx. 10°C above nominal temperature
Temperature control over- and undertemperature monitor TWW, protection class 3.3 or adjustable temperature limiter TWB, protection class 2, selectable on display
AutoSAFETY additionally integrated over- and undertemperature protection "ASF", automatically following the setpoint value at a preset tolerance range, alarm in case of over- or undertemperature, heating is switched off in case of overtemperature, compressor in case of undertemperature
Autodiagnostic system integral fault diagnostics for temperature and humidity control
Alarm visual and acoustic

Heating concept

Air jacket air jacket heating system for gentle all-around heating
Heating concept no drying-up of the load caused by the cooling device due to separation of thermal jacket from interior
Defrosting highly efficient automatic defrosting system

Standard equipment

Works calibration certificate standard values +10 °C and +37 °C, 60 % rh at +30 °C
Entry port Entry port (silicone), 40 mm clear diameter, moisture tight, can be closed by a silicone stopper, standard position at the back
Internals 2 stainless steel grid(s), electropolished
Standard accessories Water tank including connection hose

Stainless steel interior

Dimensions w(A) x h(B) x d(C): 560 x 480 x 400 mm (d less 33 mm for fan)
Volume 108 l
Max. number of internals 5
Max. loading of chamber 150 kg
Max. loading per internal 20 kg

Textured stainless steel casing

Dimensions w(D) x h(E) x d(F): 745 x 1233 x 585 mm (d +56mm door handle)
Installation on lockable castors
Housing rear zinc-plated steel

Electrical data

Voltage Electrical load 230 V, 50/60 Hz
approx. 1450 W
Voltage Electrical load 115 V, 50/60 Hz
approx. 1450 W

Ambient conditions

Set Up The distance between the wall and the rear of the appliance must be at least 15 cm. The clearance from the ceiling must not be less than 20 cm and the side clearance from walls or nearby appliances must not be less than 5 cm.
Ambient temperature 15 °C to 28 °C (up to 34 °C with limited temperature range)
Humidity rh max. 70 %, non-condensing
Altitude of installation max. 2,000 m above sea level
Overvoltage category II
Pollution degree 2

Packing/shipping data

Transport information The appliances must be transported upright
Customs tariff number 8419 8998
Country of origin Federal Republic of Germany
WEEE-Reg.-No. DE 66812464
Dimensions approx incl. carton w x h x d: 880 x 1410 x 810 mm
Net weight approx. 109 kg
Gross weight carton approx. 137 kg